RGT Technology, LLC . . .
Part Number | Manufacturer | Description | Brand | Price & Lead Time |
---|---|---|---|---|
100U Indoor | INGETEAM | Ingeteam 100U Indoor Series Commercial Central Inverter, Isolated Topology 100 kW @ 45˚C (Rated Continuous Power) | 600 Vdc (Max. Voc) | 1 MPPT Circuit | 300-600 Vdc MPPT Range | 300 Vdc PV Start Voltage | 350 Adc (Max. DC Input Current) | 600 W Minimum DC Power Throughput | 208 | 480 Vac Nominal Output Voltage | 4-wire with Neutral AC Output Wiring | 317 | 137 Aac Max. Output Current | 2,559 lbs Weight | with Forklift, Eyebolts Lifting Provisions Simple Type: Commercial Central Inverter | Request Quote | |
125U Outdoor | INGETEAM | Ingeteam 125U Outdoor Series Commercial Central Inverter, Isolated Topology 125 kW @ 50˚C (Rated Continuous Power) | 1,000 Vdc (Max. Voc) | 1 MPPT Circuit | 330-820 Vdc MPPT Range | 300 Vdc PV Start Voltage | 390 Adc (Max. DC Input Current) | 600 W Minimum DC Power Throughput | 208 | 480 Vac Nominal Output Voltage | 3-wire with Neutral AC Output Wiring | 347 | 151 Aac Max. Output Current | 2,645 lbs Weight | with Forklift, Eyebolts Lifting Provisions Simple Type: Commercial Central Inverter | Request Quote | |
250T U X480 Outdoor | INGETEAM | Ingeteam 250T U X480 Outdoor Series Commercial Central Inverter, Isolated Topology 250 kW @ 50˚C (Rated Continuous Power) | 1,000 Vdc (Max. Voc) | 1 MPPT Circuit | 350-820 Vdc MPPT Range | 300 Vdc PV Start Voltage | 780 Adc (Max. DC Input Current) | 1,200 W Minimum DC Power Throughput | 480 Vac Nominal Output Voltage | 3-wire with Neutral AC Output Wiring | 301 Aac Max. Output Current | 5,952 lbs Weight | with Forklift, Eyebolts Lifting Provisions Simple Type: Commercial Central Inverter | Request Quote | |
375T U X480 Outdoor | INGETEAM | Ingeteam 375T U X480 Outdoor Series Commercial Central Inverter, Isolated Topology 375 kW @ 50˚C (Rated Continuous Power) | 1,000 Vdc (Max. Voc) | 1 MPPT Circuit | 350-820 Vdc MPPT Range | 300 Vdc PV Start Voltage | 1,170 Adc (Max. DC Input Current) | 1,800 W Minimum DC Power Throughput | 480 Vac Nominal Output Voltage | 3-wire with Neutral AC Output Wiring | 451 Aac Max. Output Current | 8,047 lbs Weight | with Forklift, Eyebolts Lifting Provisions Simple Type: Commercial Central Inverter | Request Quote | |
500T U X480 Outdoor | INGETEAM | Ingeteam 500T U X480 Outdoor Series Commercial Central Inverter, Isolated Topology 500 kW @ 50˚C (Rated Continuous Power) | 1,000 Vdc (Max. Voc) | 1 MPPT Circuit | 350-820 Vdc MPPT Range | 300 Vdc PV Start Voltage | 1,560 Adc (Max. DC Input Current) | 2,400 W Minimum DC Power Throughput | 480 Vac Nominal Output Voltage | 3-wire with Neutral AC Output Wiring | 601 Aac Max. Output Current | 10,360 lbs Weight | with Forklift, Eyebolts Lifting Provisions Simple Type: Commercial Central Inverter | Request Quote | |
Central Inverter | INGETEAM | Ingeteam Central Inverters Simple Type: Central Inverter | Request Quote | |
Commercial Central Inverter | INGETEAM | Ingeteam Commercial Central Inverters Simple Type: Commercial Central Inverter | Request Quote | |
Inverter | INGETEAM | Ingeteam Inverters Simple Type: Inverter | Request Quote |