Filter by Category
Unavailable
RGT Technology, LLC . . .
Part Number | Manufacturer | Description | Brand | Price & Lead Time |
---|---|---|---|---|
RME1-AI-100-00-80-IA3 | EXEMYS | Acquired information can be read through Ethernet in four different ways. With RME1-AI you can aquire analog values in 4-20 mA, 0-10 Volts or 0-10 Volts format in a an accurate and unexpensive way throug Ethernet in four different ways (Modbus TCP, Web Page (HTTP), SNMP, CSV, XML). INPUTS 8 PROTOCOLS SERIAL PORTS 1 RS232 (*Configuration Serial Port.) INPUT TYPE 4-20mA - 0-10V. Simple Type: Analog Modules | Request Quote | |
RME1-AI-100-00-80-IA3-V100 | EXEMYS | Acquired information can be read through Ethernet in four different ways. With RME1-AI you can aquire analog values in 4-20 mA, 0-10 Volts or 0-10 Volts format in a an accurate and unexpensive way throug Ethernet in four different ways (Modbus TCP, Web Page (HTTP), SNMP, CSV, XML). INPUTS 8 PROTOCOLS SERIAL PORTS 1 RS232 (*Configuration Serial Port.) INPUT TYPE 0-100V. Simple Type: Analog Modules | Request Quote | |
RMS1-AI-110-00-80-IA3-MBHL | EXEMYS | RMS1-AI is an analog module with serial communication under Modbus ASCII/RTU protocol as a slave or under Hostlink (OMROM®) as a master. With RMS1-AI you can acquire analog values in 4-20 mA, 0-10 Volts or 0-100Volts format in an accurate and unexpensive way under serial Modbus ASCII/RTU or Hostlink (OMROM®) protocols. It provides an integral solution for applications with remote monitoring, without additional modules. INPUTS 8 PROTOCOLS MODBUS ASCII / RTU (Slave) Hostlink (Master) SERIAL PORTS 1 RS232 1 RS485 INPUT TYPE 4-20mA 0-10V. Simple Type: Analog Modules | Request Quote | |
RMS1-AI-110-00-80-IA3-MBHL-V100 | EXEMYS | RMS1-AI is an analog module with serial communication under Modbus ASCII/RTU protocol as a slave or under Hostlink (OMROM®) as a master. With RMS1-AI you can acquire analog values in 4-20 mA, 0-10 Volts or 0-100Volts format in an accurate and unexpensive way under serial Modbus ASCII/RTU or Hostlink (OMROM®) protocols. It provides an integral solution for applications with remote monitoring, without additional modules. INPUTS 8 PROTOCOLS MODBUS ASCII / RTU (Slave) Hostlink (Master) SERIAL PORTS 1 RS232 1 RS485 INPUT TYPE 0-100V. Simple Type: Analog Modules | Request Quote | |
RMS1-TD-010-00-40-IA4-MB | EXEMYS | RMS1-TD is a temperature acquisition module with serial slave Modbus communication. Accurate, yet inexpensive means of obtaining temperature readings through slave Modbus RTU. Provides an end-to-end solution for remote monitoring applications. No additional modules required. INPUTS 4 PROTOCOLS MODBUS RTU (Slave) SERIAL PORT 1 RS485 INPUT TYPE TEMP. PROBE Simple Type: Analog Modules | Request Quote | |
RMS1-TD-100-00-40-IA4-MB | EXEMYS | RMS1-TD is a temperature acquisition module with serial slave Modbus communication. Accurate, yet inexpensive means of obtaining temperature readings through slave Modbus RTU. Provides an end-to-end solution for remote monitoring applications. No additional modules required. INPUTS 4 PROTOCOLS MODBUS RTU (Slave) SERIAL PORT 1 RS232 INPUT TYPE TEMP. PROBE Simple Type: Analog Modules | Request Quote |