Filter by Category
Unavailable
RGT Technology, LLC . . .
Part Number | Manufacturer | Description | Brand | Price & Lead Time |
---|---|---|---|---|
CAB327 | DATALOGIC | Datalogic CAB327 Cable 9-Pin RS-232 For Data Logic Scanners Simple Type: Cable | Request Quote | |
CAB-348 BO26 | DATALOGIC | Datalogic - DATALOGIC,CAB-348,9F COILED LIGHT PEN EMULATION Simple Type: ADDITIONAL PRODUCTS | Request Quote | |
CAB-6005 | DATALOGIC | Datalogic - DATALOGIC,CABLE,6300 TO C-BOX, 5 METER,(93A051210) Simple Type: ADDITIONAL PRODUCTS | Request Quote | |
CBL-1167 | DATALOGIC | CABLE ASSEMBLY FOR LS50 Simple Type: TBD | Request Quote | |
CBL-1178 | DATALOGIC | CABLE ASSEMBLY Simple Type: TBD | Request Quote | |
CBL-1229 | DATALOGIC | CABLE ASSEMBLY Simple Type: TBD | Request Quote | |
CBL-1230 | DATALOGIC | Datalogic CBL-1230 Demonstration Cable for RS427-10. Includes RS232 cable with DE-9 terminating connectors, power supply, EC communication program Simple Type: Cable | Request Quote | |
CBL-1233 | DATALOGIC | CABLE ASSEMBLY Simple Type: TBD | Request Quote | |
CBL-1234 | DATALOGIC | CABLE ASSEMBLY Simple Type: Cable | Request Quote | |
CBL-1243 | DATALOGIC | CABLE ASSEMBLY Simple Type: TBD | Request Quote | |
CBOX100 | DATALOGIC | DATALOGIC CBOX100 Fixed Position 2D Readers Junction/Control Boxes Simple Type: NYC The C-Box Line is equipped with an internal terminal block made of practical spring clamps and 5 external cable glands for easy cabling operations. Connection to the scanner is made through an external standard D-Shell 25 pin connector. All models have an internal standard D-Shell 9 pin connector to access the auxiliary service interface of the scanner. The ease of use is enhanced thanks to an internal switch and Led, which control the power supply status, and a practical external display and keypad (C-Box 310/410). Download the datasheet (PDF) | Request Quote | |
C-BOX-100 | DATALOGIC | DATALOGIC C-Box Module Simple Type: TBD | Request Quote | |
CHS1265-IND-01 | DATALOGIC | Datalogic CHS1265-IND-01 Low Frequency RFID Controller / Antenna, Industrial Ethernet Simple Type: RFID Controller Rugged, highly connected COBALT RFID systems provide easily integrated and economical solutions for Auto-ID on the factory floor. Dust and moisture protection assure years of reliable operation in harsh environments. The Cobalt HS RFID controller/antenna operates with EMS’ HS series of very high memory RFID tags. 25+ years of experience with RFID systems for manufacturing are behind every EMS system, supported by Datalogic around the world. Download the datasheet (PDF) | Request Quote | |
CM1000 | DATALOGIC | Datalogic CM1000 RFID Module Simple Type: RFID Module The CM1000 achieves high data exchange rates by using three independent high-speed microprocessors in an advanced multiprocessor architecture. A master microprocessor executes the standard program or the user written application program while communicating with the backplane and with the two slave microprocessors. The master microprocessor system provides 32KB of battery backed RAM for storage of runtime variables, pointers, and inprocess data transactions,as well as 32KB of ultra-reliable non-volatileEEPROM for program storage. The RFID slave microprocessor is dedicated to communications with the RFID data collection ports. The use of a separate microprocessor for this function insures maximum performance. The RFID subsystem has its own 32KB of RAM for data buffering and a dual port RAM for communication with the master microprocessor, and can control up to four Read/Write Antennas. Connection to the RFID Antennas is via a Phoenix-type plug-in terminal strip.The second slave microprocessor system is dedicated to control of the eight bi-directional serial ports, which can be used to interface to bar code scanners or other serial interface devices. Each serial port is software-selectable for RS232 or RS422 interfaces. Download the datasheet (PDF) | Request Quote | |
CM11 | DATALOGIC | Datalogic CM11 DeviceNet Interface Module Simple Type: Interface Module | Request Quote | |
CM1746 | DATALOGIC | Datalogic CM1746 RFID Module. ALLEN BRADLEY PLC INTERFACE RF ID SYSTEM | 25 MHz i386 Processor | 512KB Flash Memory | 512KB RAM | DOS Compatible Operating System | LED Status Indicators Simple Type: RFID Module Escort Memory Systems’ CM1746 RFID module is a plug-in module for the Allen-Bradley SLC 500 programmable controller family with 1746 backplane. With the CM1746, the Allen-Bradley PLC has access to information in the Escort Memory Systems’ HS/HL and HMS-Series read/write tags and ES-Series read only tags. The powerful programmable processor in the CM1746 regulates serial and RFID transfers thus freeing the PLC from communication tasks with Escort Memory Systems devices. The CM1746 plugs directly into the PLC backplane using the PLC’s 1746 technology bus. It has the same mechanical housing, backplane connections, and interface protocols found in other Allen-Bradley modules for the SLC 500 family. The CM1746 benefits from the proven reliability and durability of this PLC family. Two ports are dedicated to HS500-Series and HL500-Series read/write antennas, while HMS-Series Reader/Writers and RS Read Only antennas must be connected to a serial port. The HMS800 and HMS805 are RS232 communications only and two may be connected to the CM1746 through COM1 and COM2. COM1 is used to load the new software into the CM1746 or for point-topoint RS232 connection. The COM2 serial port also supports MUX32/RS485 protocol. There are special commands in the standard program for addressing slave devices on the multidrop line. For other serial devices the COM2 port may be configured as an RS232, RS422 or RS485 serial port. A DOS compatible processor makes it easy for a user to program the CM1746. An industry standard compiler gives the user a familiar, inexpensive and well supported development environment. A general purpose optically isolated digital input is provided for connection of a presence sensor, proximity sensor, or relay. An optically isolated output can be used to send trigger signals to readers, or to operate a relay coil. Download the datasheet (PDF) | Request Quote | |
CM21 | DATALOGIC | Datalogic CM21 Scanner - MODULE SCANNER INTERBUS-S RS232/RS485 MUX32 Simple Type: Scanner | Request Quote | |
CM21L004 | DATALOGIC | MODULE Simple Type: Interface Module | Request Quote | |
CM31 | DATALOGIC | Datalogic CM31 Profibus Bus Module. Profibus DP Communication Module, NEMA 4 Simple Type: RFID Module Download the datasheet (PDF) | Request Quote | |
CM42 | DATALOGIC | Datalogic CM42 Interface Module-Escort Memory Systems (EMS) CM42 Modbus Plus module Simple Type: Interface Module The CM40-Series Modbus Plus Modules are general purpose programmable interface devices between the Modbus Plus network and up to two HS500-Series Antennas, or as many as 32 HMS-Series Reader/Writers, RS-Series Readers or bar code scanners (or a combination of both) on a MUX32 line. The CM41 features a durable NEMA 4 enclosure while the CM42 is encased in an ABS NEMA 2 shell. The field-proven 386 microprocessor and a real-time DOS compatible operating system provide reliability, speed and flexibility. Download the datasheet (PDF) | Request Quote | |
CM52 | DATALOGIC | Datalogic CM52 Remote I/O Module. Mod Bus Plus | 24 VDC | 350MA Simple Type: I/O Module The CM52 Remote I/O (RIO) module is a general purpose programmable interface between the Allen-Bradley (A-B) Remote I/O network and Escort Memory Systems RFID (Radio Frequency Identification) equipment, or third party products. The CM52 interfaces to a variety of devices: two EMS HS/HL500-Series antennas; twoHMS8xx series antennas; two serial ports; and as many as 32HMS-Series Reader/Writers, RS-Series Read Only antennas, or bar code scanners (or combinations) on an RS485MUX32 line. | Request Quote | |
CM81 | DATALOGIC | Datalogic CM81 ControlNet Module Simple Type: ControlNet Controller The CM81 ControlNet Module is a general purpose programmable interface between the controlNet network and up to two HS/HL500-Series Antennas, or as many as 32 HMS-Series Reader/Writers, RS-Series Readers or bar code scanners (or a combination of both) on a Mux32 line. The CM81 supports ControlNet with a variable mix of baud. The CM81 can be used to give a ControlNet presence to a wide range of existing equipment, such as bar code readers, RFID Controllers, bar code verifiers, sensors and switches. This programmable interface is provided with a standard program that allows ControlNet commands to control the reading and writing of a block (or non-contiguous blocks) of data, Mux32 connection status, serial inputs/outputs, and Tag fill functions. The module is based on a real-time, DOS compatible operating system providing great speed and flexibility. As many as four commands can be processed simultaneously. The CM81 is implemented as a two board set, interconnected by a stackable PC104 Connector. Download the datasheet (PDF) | Request Quote | |
CM900 | DATALOGIC | AUTO ID MODULE Simple Type: NYC The CM900 Automatic ID module, developed together with Modicon through the ModConnect Partners program, allows all serial devices as well as bar code and Read/Write Radio Frequency Identification (RFID) products, to be connected directly to the Modicon Compact series backplane and Micro I/O expansion bus. The CM900 expands the role of the Compact PLC by adding ASCII data handling capability. | Request Quote |