RGT Technology, LLC . . .

Filter by Category
Not available
Filter by Manufacturer
Part Number Manufacturer Description Brand Price & Lead Time
705-1 HIPOTRONICS 0-5 AC Output Voltage, 200 AC Output Current, 1 Power1 (kVA) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
705-10 HIPOTRONICS 0-5 AC Output Voltage, 2000 AC Output Current, 10 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single Phase) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
705-2 HIPOTRONICS 0-5 AC Output Voltage, 400 AC Output Current, 2 Power1 (kVA), 50/60Hz Std. Input2 (Single Phase) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
705-20 HIPOTRONICS 0-5 AC Output Voltage, 4000 AC Output Current, 20 Power1 (kVA), 380V, 480 V, or 600V, Std. Input2 (Single Phase) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Download the datasheet (PDF) Request Quote
705-40 HIPOTRONICS 0-5 AC Output Voltage, 8000 AC Output Current, 40 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
705-5 HIPOTRONICS 0-5 AC Output Voltage, 1000 AC Output Current, 5 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single Phase) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
705-60 HIPOTRONICS ETH LAN BOARD 10MB PCI Simple Type: AC DIELECTRIC TEST SETS Request Quote
7100-10 HIPOTRONICS 0-100 AC Output Voltage, 100 AC Output Current, 10 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
7100-100 HIPOTRONICS 0-100 AC Output Voltage, 1000 AC Output Current, 100 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
7100-150 HIPOTRONICS 0-100 AC Output Voltage, 1500 AC Output Current, 150 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
7100-20 HIPOTRONICS 0-100 AC Output Voltage, 200 AC Output Current, 20 Power1 (kVA), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
7100-200 HIPOTRONICS 0-100 AC Output Voltage, 2000 AC Output Current, 200 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
7100-40 HIPOTRONICS 0-100 AC Output Voltage, 400 AC Output Current, 40 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
7100-5 HIPOTRONICS 0-100 AC Output Voltage, 50 AC Output Current, 5 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
7100-60 HIPOTRONICS 0-100 AC Output Voltage, 600 AC Output Current, 60 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
710-1 HIPOTRONICS 0-10 AC Output Voltage, 100 AC Output Current, 1 Power1 (kVA) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
710-10 HIPOTRONICS 0-10 AC Output Voltage, 1000 AC Output Current, 10 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single Phase) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
710-2 HIPOTRONICS 0-10 AC Output Voltage, 200 AC Output Current, 2 Power1 (kVA) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
710-20 HIPOTRONICS 0-10 AC Output Voltage, 2000 AC Output Current, 20 Power1 (kVA), 50/60Hz Std. Input2 (Single Phase) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
710-40 HIPOTRONICS 0-10 AC Output Voltage, 4000 AC Output Current, 40 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
710-5 HIPOTRONICS 0-10 AC Output Voltage, 500 AC Output Current, 5 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single Phase) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
710-60 HIPOTRONICS 0-10 AC Output Voltage, 6000 AC Output Current, 60 Power1 (kVA), 480 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
7125-10 HIPOTRONICS 0-125 AC Output Voltage, 80 AC Output Current, 10 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single Phase), Oil Insulation with Steel tank type Simple Type: AC DIELECTRIC TEST SETS Request Quote
715-1 HIPOTRONICS 0-15 AC Output Voltage, 67 AC Output Current, 1 Power1 (kVA) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote
715-10 HIPOTRONICS 0-15 AC Output Voltage, 667 AC Output Current, 10 Power1 (kVA), 230 Vac, 50/60Hz Std. Input2 (Single Phase) with Air Insulation Simple Type: AC DIELECTRIC TEST SETS Request Quote